{"schemaVersion":1,"controlId":"ISM-2008","status":"current","latestVersion":"v2026.09.4","firstSeen":"v2025.03.31","lastSeen":"v2026.09.4","removedIn":null,"presentIn":9,"control":{"controlId":"ISM-2008","version":"v2026.09.4","title":"ISM-2008","displayTitle":"Bringing medical devices into facilities","chapter":"Guidelines for physical security","section":"Facilities and systems / Bringing medical devices into facilities","topic":"Bringing medical devices into facilities","path":["Guidelines for physical security","Facilities and systems","Bringing medical devices into facilities"],"statement":"Medical devices authorised to be brought into SECRET and TOP SECRET areas meet, at a minimum, the following criteria: - are listed on the Australian Register of Therapeutic Goods - have been prescribed by a legally qualified medical practitioner - have been commercially purchased within Australia - do not have inbuilt cellular connectivity - can operate independently of mobile devices - where possible, have Wi-Fi, Bluetooth and other forms of wireless connectivity disabled when operating within SECRET and TOP SECRET areas.","revision":"1","updated":"Jun-26","applicability":["S","TS"],"applicabilityLabels":["SECRET","TOP SECRET"],"essentialEight":[]},"lastSeenControl":null,"history":[{"type":"introduced","version":"v2025.03.31","baseline":false},{"type":"changed","version":"v2026.06.18","previousVersion":"v2026.03.24","fields":["statement","revision","updated"],"changes":{"statement":{"before":"Medical devices that are authorised to be brought into SECRET and TOP SECRET areas meet, at a minimum, the following criteria: - are listed on the Australian Register of Therapeutic Goods - have been prescribed by a legally qualified medical practitioner - have been commercially purchased within Australia - do not have inbuilt cellular connectivity - are capable of operating independently of mobile devices - where possible, have Wi-Fi, Bluetooth and other forms of wireless connectivity disabled when operating within SECRET and TOP SECRET areas.","after":"Medical devices authorised to be brought into SECRET and TOP SECRET areas meet, at a minimum, the following criteria: - are listed on the Australian Register of Therapeutic Goods - have been prescribed by a legally qualified medical practitioner - have been commercially purchased within Australia - do not have inbuilt cellular connectivity - can operate independently of mobile devices - where possible, have Wi-Fi, Bluetooth and other forms of wireless connectivity disabled when operating within SECRET and TOP SECRET areas."},"revision":{"before":"0","after":"1"},"updated":{"before":"Mar-25","after":"Jun-26"}}}]}