{"schemaVersion":1,"controlId":"ISM-0248","status":"removed","latestVersion":"v2026.09.4","firstSeen":"v2022.09.14","lastSeen":"v2024.10.4","removedIn":"v2024.12.19","presentIn":16,"control":null,"lastSeenControl":{"controlId":"ISM-0248","version":"v2024.10.4","title":"ISM-0248","displayTitle":"Emanation security threat assessments","chapter":"Guidelines for Communications Infrastructure","section":"Emanation security / Emanation security threat assessments","topic":"Emanation security threat assessments","path":["Guidelines for Communications Infrastructure","Emanation security","Emanation security threat assessments"],"statement":"System owners deploying OFFICIAL: Sensitive or PROTECTED systems with radio frequency transmitters (including any wireless capabilities) that will be located within 20 meters of SECRET or TOP SECRET systems contact ASD for an emanation security threat assessment.","revision":"8","updated":"Dec-23","applicability":["OS","P"],"applicabilityLabels":["OFFICIAL: Sensitive","PROTECTED"],"essentialEight":[]},"history":[{"type":"introduced","version":"v2022.09.14","baseline":true},{"type":"changed","version":"v2023.09.21","previousVersion":"v2023.08.3","fields":["statement","revision","updated","applicability"],"changes":{"statement":{"before":"System owners deploying OFFICIAL or PROTECTED systems with Radio Frequency transmitters that will be co-located with SECRET or TOP SECRET systems contact the ACSC for an emanation security threat assessment and implement any additional installation criteria derived from the threat assessment.","after":"System owners deploying OFFICIAL: Sensitive or PROTECTED systems with Radio Frequency transmitters that will be co-located with SECRET or TOP SECRET systems contact ASD for an emanation security threat assessment and implement any additional installation criteria derived from the threat assessment."},"revision":{"before":"6","after":"7"},"updated":{"before":"Dec-21","after":"Sep-23"},"applicability":{"before":["O","P"],"after":["OS","P"]}}},{"type":"changed","version":"v2023.12.1","previousVersion":"v2023.09.25","fields":["statement","section","topic","revision","updated"],"changes":{"statement":{"before":"System owners deploying OFFICIAL: Sensitive or PROTECTED systems with Radio Frequency transmitters that will be co-located with SECRET or TOP SECRET systems contact ASD for an emanation security threat assessment and implement any additional installation criteria derived from the threat assessment.","after":"System owners deploying OFFICIAL: Sensitive or PROTECTED systems with radio frequency transmitters (including any wireless capabilities) that will be located within 20 meters of SECRET or TOP SECRET systems contact ASD for an emanation security threat assessment."},"section":{"before":"Emanation security / Emanation security threat assessments in Australia","after":"Emanation security / Emanation security threat assessments"},"topic":{"before":"Emanation security threat assessments in Australia","after":"Emanation security threat assessments"},"revision":{"before":"7","after":"8"},"updated":{"before":"Sep-23","after":"Dec-23"}}},{"type":"removed","version":"v2024.12.19","previousVersion":"v2024.10.4"}]}